人骨成型蛋白受體1A(BMPR-1A)elisa試劑盒北京供應(yīng)
中文名稱:人骨成型蛋白受體1A(BMPR-1A)
把時(shí)間留給思考,把實(shí)驗(yàn)交給方程生物,專業(yè)的人做專業(yè)的事情,更高效!
本試劑盒應(yīng)用雙抗體夾心法測(cè)定標(biāo)本中人骨成型蛋白受體1A(BMPR-1A)水平。用純化的抗體包被微孔板,制成固相抗體,往包被單抗的微孔中依次加入,再與HRP標(biāo)記的結(jié)合,形成抗體-抗原-酶標(biāo)抗體復(fù)合物,經(jīng)過(guò)*洗滌后加底物TMB顯色。TMB在HRP酶的催化下轉(zhuǎn)化成藍(lán)色,并在酸的作用下轉(zhuǎn)化成zui終的黃色。顏色的深淺和樣品中的呈正相關(guān)。用酶標(biāo)儀在450nm波長(zhǎng)下測(cè)定吸光度(OD值),通過(guò)標(biāo)準(zhǔn)曲線計(jì)算樣品中的濃度。
The E-Z 96? Mag-Bind? Tissue RNA Kit provides a novel technology for total RNA isolation from plant and animal tissues. This kit allows the rapid and reliable isolation of high-quality total cellular RNA from a wide variety of tissues. Samples are first lysed in a specially formulated buffer and then proteins and DNA are precipitated. The Supertanent is combined with magentic beads and after a couple of quick wash steps pure RNA is eluted. Unlike column-based systems, the binding of nucleic acids to magnetic partciles occurs in solution, resulting in increased binding kinetics and binding efficiency. Particles are also completly re-suspended during the wash steps of the purification protocol, which enhances contact with the wash buffer and removal of contaminants and increasing nucleic acid purity. E.Z.N.A.? Mag-Bind? Tissue RNA procedure can be automated with most robotic workstations。
結(jié)果判斷1、 定性測(cè)定定性測(cè)定的結(jié)果判斷是對(duì)受檢標(biāo)本中是否含有待測(cè)抗原或抗體作出"有"或"無(wú)"的簡(jiǎn)單回答,分別用"陽(yáng)性"、"陰性"表示。"陽(yáng)性"表示該標(biāo)本在該測(cè)定系統(tǒng)中有反應(yīng)。"陰性"則為無(wú)反應(yīng)。用定性判斷法也可得到半定量結(jié)果,即用滴度來(lái)表示反應(yīng)的強(qiáng)度,其實(shí)質(zhì)仍是一個(gè)定性試驗(yàn)。在這種半定量測(cè)定中,將標(biāo)本作一系列稀釋后進(jìn)行試驗(yàn),呈陽(yáng)性反應(yīng)的zui高稀釋度即為滴度。根據(jù)滴度的高低,可以判斷標(biāo)本反應(yīng)性的強(qiáng)弱,這比觀察不稀釋標(biāo)本呈色的深淺判斷為強(qiáng)陽(yáng)性、弱陽(yáng)性更具定量意義。在間接法和夾心法ELSIA中,陽(yáng)性孔呈色深于陰性孔。在競(jìng)爭(zhēng)法ELISA中則相反,陰性孔呈色深于陽(yáng)性孔。兩類反應(yīng)的結(jié)果判斷方法不同,分述于下。(1) 間接法和夾心法這類反應(yīng)的定性結(jié)果可以用肉眼判斷。目視標(biāo)本也無(wú)色或近于無(wú)色者判為陰性,顯色清晰者為陽(yáng)性。但在ELSIA中,正常人血清反應(yīng)后??沙霈F(xiàn)呈色的本底,此本底的深淺因試劑的組成和實(shí)驗(yàn)的條件不同而異,因此實(shí)驗(yàn)中必須加測(cè)陰性對(duì)照。陰性對(duì)照的組成應(yīng)為不含受檢物的正常血清或類似物(見(jiàn)3.6)。在用肉眼判斷結(jié)果時(shí),更宜用顯色深于陰性對(duì)照作為標(biāo)本陽(yáng)性的指標(biāo)。目視法簡(jiǎn)捷明了,但頗具主觀性。在條件許可下,應(yīng)該用比色計(jì)測(cè)定吸光值,這樣可以得到客觀的數(shù)據(jù)。先讀出標(biāo)本(sample,S)、陽(yáng)性對(duì)照(P)、和陰性對(duì)照(N)的吸光值,然后進(jìn)行計(jì)算。計(jì)算方法有多種,大致可分為陽(yáng)性判定值法和標(biāo)本與陰性對(duì)照比值法兩類。a. 陽(yáng)性判定值陽(yáng)性判定值(cut-off value)一般為陰性對(duì)照A值加上一個(gè)特定的常數(shù),以此作為判斷結(jié)果陽(yáng)性或陰性的標(biāo)準(zhǔn)。用此法判斷結(jié)果要求實(shí)驗(yàn)條件十分恒定,試劑的制備必須標(biāo)準(zhǔn)化,陽(yáng)性和陰性的對(duì)照品應(yīng)符合一定的規(guī)格,須配用精密的儀器,并嚴(yán)格按規(guī)定操作。陽(yáng)性判定值公式中的常數(shù)是在這特定的系統(tǒng)中通過(guò)對(duì)大量標(biāo)本的實(shí)驗(yàn)檢測(cè)而得到的。現(xiàn)舉某種檢測(cè)HBsAg的試劑盒為例。試劑盒中的陰性對(duì)照品為不含HBsAg的復(fù)鈣人血漿,陽(yáng)性對(duì)照品HBsAg的含量標(biāo)明為P=9±2ng/ml.每次試驗(yàn)設(shè)2個(gè)陽(yáng)性對(duì)照和3個(gè)陰性對(duì)照。測(cè)得A值后,先計(jì)算陰性對(duì)照A值的平均數(shù)(NCX)和陽(yáng)性對(duì)照A值的平均數(shù)(PCX),兩個(gè)平均數(shù)的差(P-N)必須大于一個(gè)特定的數(shù)值(例0.400),試驗(yàn)才有效。3個(gè)陰性對(duì)照A值均應(yīng)≥0.5×NCX,并≤1.5×NCX,如其中之一超出此范圍,則棄去,而已另兩個(gè)陰性對(duì)照重新計(jì)算NCX如有兩個(gè)陰性對(duì)照A值超出以上范圍,則該次實(shí)驗(yàn)無(wú)效。陽(yáng)性判定值按下式計(jì)算: 陽(yáng)性判定值=NCX+0.05 標(biāo)本A值>陽(yáng)性判定值的為陽(yáng)性,小于陽(yáng)性判定值的為陰性。應(yīng)注意的是,式中0.05為該試劑盒的常數(shù),只適合于該特定條件下,而不是對(duì)各種試劑均可通用。根據(jù)以上敘述可以看出,在這種方法中陰性對(duì)照和陽(yáng)性對(duì)照也起到試驗(yàn)的質(zhì)控作用,試劑變質(zhì)和操作不當(dāng)均會(huì)產(chǎn)生"試驗(yàn)無(wú)效"的后果。b.標(biāo)本/陰性對(duì)照比值在實(shí)驗(yàn)條件(包括試劑)較難保證恒定的情況下,這種判斷法較為合適。在得出標(biāo)本(S)和陰性對(duì)照(N)的A值后,計(jì)算S/N值。也有寫(xiě)作P/N的,這里的P不代表陽(yáng)性(positive),而是病人(patient)的縮寫(xiě),不應(yīng)誤解。為避免混淆,更宜用S/N表示。在早期的間接法ELISA中,有些作者定出S/N為陽(yáng)性標(biāo)準(zhǔn),現(xiàn)多為各種測(cè)定所沿用。實(shí)際上每一測(cè)定系統(tǒng)應(yīng)該用實(shí)驗(yàn)求出各自的S/N的閾值。更應(yīng)注意的是,N所代表的陰性對(duì)照是不含受檢物質(zhì)的人血清。有的試劑盒中所設(shè)陰性對(duì)照為不含蛋白質(zhì)或蛋白質(zhì)含量較底的緩沖液,以致反應(yīng)后產(chǎn)生的本底可能較正常人血清的本底低得多。因此,這類試劑盒規(guī),如N<0.05(或其他數(shù)值),則按0.05計(jì)算,否則將出現(xiàn)假陽(yáng)性結(jié)果。(2)競(jìng)爭(zhēng)法在競(jìng)爭(zhēng)法ELISA中,陰性孔呈色深于陽(yáng)性孔。陰性呈色的強(qiáng)度取決于反應(yīng)中酶結(jié)合物的濃度和加入競(jìng)爭(zhēng)抑制物的量,一般調(diào)節(jié)陰性對(duì)照的吸光度在1.0-1.5之間,此時(shí)反應(yīng)zui為敏感。 競(jìng)爭(zhēng)法ELISA不易用自視判斷結(jié)果,因肉眼很難辨別弱陽(yáng)性反應(yīng)與陰性對(duì)照的顯色差異,一般均用比色計(jì)測(cè)定,讀出S、P和N的吸光值。計(jì)算方法主要也有兩種,即陽(yáng)性判定值法和抑制率法。a. 陽(yáng)性判定值法與間接法和夾心法中的陽(yáng)性判定值法基本相同,但在計(jì)算公式中引入陽(yáng)性對(duì)照A值,現(xiàn)舉某種檢測(cè)抗HBc的試劑盒為例。試劑盒中的陰性對(duì)照為不含抗HBc的復(fù)鈣人血漿,陽(yáng)性對(duì)照中抗HBc含量為125±100u/ml.每次試驗(yàn)設(shè)2個(gè)陽(yáng)性對(duì)照和3個(gè)陰性對(duì)照。測(cè)得A值后,先計(jì)算陰性對(duì)照A值的平均值(NCX)和陽(yáng)性對(duì)照A值的平均數(shù)(PCX),兩個(gè)平均數(shù)的差(N-P)必須大于一個(gè)特定的數(shù)值(例如0.300),試驗(yàn)才有效。3個(gè)陰性對(duì)照A值均應(yīng)小于2.000,而且應(yīng)≥0.5×NCX并≤1.5×NCX,如其中之一超出此范圍,則棄去,而以另2個(gè)陰性對(duì)照重新計(jì)算×NCX如有2個(gè)陰性對(duì)照A超出以上范圍,則該次實(shí)驗(yàn)無(wú)效。陽(yáng)性判定值按下式計(jì)算:陰性判定值=0.4×NCX+0.6×PCX2、定量測(cè)定ELISA操作步驟復(fù)雜,影響反應(yīng)因素較多,特別是固相載體的包被難達(dá)到各個(gè)體之間的*,因此在定量測(cè)定中,每批測(cè)試均須用一系列不同濃度的參考標(biāo)準(zhǔn)品在相同的條件下制作標(biāo)準(zhǔn)曲線。測(cè)定大分子量物質(zhì)的夾心法ELISA,標(biāo)準(zhǔn)曲線的范圍一般較寬,曲線zui高點(diǎn)的吸光度可接近2.0,繪制時(shí)常用半對(duì)數(shù)紙,以檢測(cè)物的濃度為橫坐標(biāo),以吸光度為縱坐標(biāo),將各濃度的值逐點(diǎn)連接,所得曲線一般呈S形,其頭、尾部曲線趨于平坦,*較呈直線的部分是的檢測(cè)區(qū)域。甲胎蛋白質(zhì)ELISA測(cè)定的標(biāo)準(zhǔn)曲線示例見(jiàn)圖4-1。測(cè)定小分子量物質(zhì)常用競(jìng)爭(zhēng)法,其標(biāo)準(zhǔn)曲線中吸光度與受檢物質(zhì)的濃度呈負(fù)相關(guān)。標(biāo)準(zhǔn)曲線的形狀因試劑盒所用模式的差別而略有不同。ELISA測(cè)定的標(biāo)準(zhǔn)曲線示例見(jiàn)圖4-2.注意圖中橫坐標(biāo)為對(duì)數(shù)關(guān)系,這更有利于測(cè)定系統(tǒng)的表達(dá)。新型酶標(biāo)儀一般帶有自動(dòng)軟件可進(jìn)行定量分析。
相關(guān)指標(biāo):
人E鈣粘著蛋白/上皮性鈣黏附蛋白(E-Cad)測(cè)定盒
人芳基硫 酸酯酶A(ASA)測(cè)定盒ELISA
人骨成型蛋白受體1A(BMPR-1A)
人胃泌素細(xì)胞抗體(GCA)測(cè)定盒
人血管生成素1(ANG-1)測(cè)定盒ELISA
人*(FK506)測(cè)定盒
人促腎上皮質(zhì)激素釋放激素(CRH)測(cè)定盒
人嗜酸性白血球相關(guān)之RNA水解酵素家族成員2(EAR2)測(cè)定盒北京代測(cè)
人補(bǔ)體3 (C3) 測(cè)定盒
人β-內(nèi)啡肽(β-EP)測(cè)定盒
人趨化因子(fractalkine/CX3CL1) 測(cè)定盒
人抗單鏈DNA抗體/變性DNA抗體(ssDNA)測(cè)定盒