The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system. Its precision signal level and attenuation, high signal purity and precision low distortion modulation make this reference source superior to the general-purpose signal generators that are often used to calibrate

詳細(xì)介紹

96040A Low Phase Noise Reference Source

靖江中諾儀器有限公司為福祿克中國(guó)總代理,歡迎!

Simplify your RF calibration system

The Fluke Calibration 96040A RF ReferenceSource enables you to simplify your RF calibration system by replacing many ofthe instruments and accessories that make up your current system. Its precisionsignal level and attenuation, high signal purity and precision low distortionmodulation make this reference source superior to the general-purpose signalgenerators that are often used to calibrate spectrum analyzers, modulationmeters, RF sensors, attenuators, and similar instruments. Its low phase noiseprovides superior phase noise performance.

Unlike many RF calibration solutions, the96040A is designed specifically for RF calibration, with a calibration-orienteduser interface that makes it easy to learn and use. The 96040A speeds upcalibration procedures, reduces opportunities for operator errors, and greatlysimplifies RF metrology. As the core of an RF and microwave calibration system,the 96040A covers the majority of test points required for calibrating spectrumanalyzers of any frequency range.

Automated with MET/CAL® Plus CalibrationManagement Software, the 96040A reduces complexity and calibration times,dramatically improving efficiency and increasing capacity by 50 % or more overmanual methods.

Key benefits

·Covers a broad range of RF calibration workload

·Reduces the number of instruments and interconnections required foryour RF calibration system

·“What you setis what you get" accurate signal delivery direct to the UUT input

·Integrated 50 MHz frequency counter eliminates need for anadditional instrument ? Calibration-specific interface simplifies technician tasks

·Simplifies uncertainty calculations by delivering known signalsdirect to the unit under test (UUT)

·Lowers RF system maintenance costs

·With automation, reduces spectrum analyzer calibration times by asmuch as 50% over manual methods

Broad, versatile workload coverage

The 96040A calibrates a broad workload ofRF calibration devices, including:

·Spectrum analyzers

·Modulation meters and analyzers

·RF power meters and sensors

·Frequency counters

·Attenuators

·And more

The metrology associated with calibratingthese items becomes simpler because you have fewer error sources anduncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research anddevelopment, manufacturing test, and ATE needing better performance than ageneral purpose signal generator. If wide frequency coverage, frequencyresolution, low harmonics, phase noise and spurious content, signal level andattenuation accuracy, or dynamic range are critical parameters the 96040A is anideal solution.

Cut the cost of your RF calibration systemin half

As the central instrument in a highcapability RF spectrum analyzer calibration system, the 96040A can cut yourcosts in half. The 96040A replaces all of these parts of a typical" RFcalibration system:

Up to four signal sources (from audio/function generators to RF signal and low phase noise sources)

·Power meters and power sensors

·Step attenuators

·Filters

·Pads

·Couplers

·50 MHz frequency counter

The 96040A not only reduces the initialneed to purchase, install and configure RF system components, but it alsoreduces the maintenance and calibration costs associated with all of thatequipment. The 96040A is also easier to transport than a heavy rack ofequipment and accessories, making it a good solution for on-site calibration.

With its 4 GHz frequency range, the 96040Aperforms more than 80 % of all the tests required on high performance, highfrequency spectrum analyzers.

For workload items that require frequenciesbeyond 4 GHz, you can use an RF and microwave source that you probably alreadyown alongside the 96040A to address the few remaining higher frequency testpoints. For many spectrum analyzer models operating below 4 GHz, you only needa 96040A to perform the entire calibration. You cant simplifymuch more than that!

No need for additional function generators

The 9640A Reference Sources internalmodulation capability makes it suitable for applications that require precisionmodulation to be applied to the output signal, such as modulation analyzercalibration and spectrum analyzer sweep time testing using an AM signal withmore accurate modulation rates. You dont need additionalfunction generators as a low frequency modulation sourcethe 96040Adelivers it all.

Designed for RF calibration

The 96040A user interface is designed tosimplify processes for calibrating typical items in your workload, such asspectrum analyzers, RF level meters and receivers. Parameter offset, stepping,relative and UUT/DUT error readout modes allow you to work accurately andefficiently, following familiar calibration procedures. Youll find iteasier than ever to determine the performance and tolerances of units undertest.

The 96040A front panel is equipped withdedicated function keys, context-sensitive softkeys, and a bright, easy-to-readcolor display that make it easy to learn and operate. You can set output levelsin terms of power (watts or dBm), voltage (RMS or peak to peak) using familiarmultipliers and exponent forms. You can move easily between voltage, power anddBm units without losing entered values or accuracy. In error readout mode toadjust the reading, simply rotate the spin wheel and the UUT error is displayeddirectly in dB, ppm or percent.

The simple, calibration-oriented userinterface also makes troubleshooting easier if you encounter an unexpectedresult or an out-of-tolerance condition while following a manual or automatedcalibration procedure.

What you set is what you get" accuracy and signalpurity

A rugged, precise levelling head delivers96040A signal levels directly to the unit under test (UUT) input just the wayyou set them on the front panel. This unique What you set is whatyou get" feature helps you avoid problems like losses, noise, interference,and mismatch errors, which can be caused by using intermediate connectors and cables.This approach also maintains the integrity of low-level signals. The headmaintains signal precision and noise immunity throughout a 154 dB dynamicrange, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from25 to just 5 during a typical calibration, allowing you to connect onceand test many," extending unattended times in an automated system, and reducingconnector wear.

靖江中諾儀器有限公司為福祿克中國(guó)總代理,歡迎!

Calibrated as a system to assure systemperformance

The 96040A is supplied with a 50 ohmleveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Eachmainframe and head are calibrated together as a complete system. Systemcalibration helps assure overall system performance. Each 96040A instrument issupplied with a comprehensive ISO 17025 compliant certificate of calibrationwith data for all key parameters, including level and attenuation, output VSWR,and phase noise. You can be assured that your 96040A is traceable, plus RFmetrology and uncertainty analysis become much simpler and faster. Accreditedcertification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized forlow and high offset frequencies and specifications from 1 Hz to 10 MHz offsets,the 96040A offers exceptional phase noise performance beyond that required fortodays high performance workloads.

Phase noise data is included in the 96040Acertificate of calibration. Instead of relying only on the more conservativeguaranteed specifications, users have actual performance data for their unit.Even with the best low phase noise signal generators, filters are commonly usedduring spectrum analyzer phase noise calibration tests, reducing noise levelsat wide (high) offset frequencies to improve test margins. The 9600FLT 1 GHzbandpass filter accessory is designed specifically for high performancespectrum analyzer wide-offset phase noise testing and connects easily to 96040Amodels in either benchtop or rack-mounted applications.

Selectable frequency reference input/output expands functionality

Selectable external frequency referenceinput is available as a standard feature on the rear panel of the 96040A. Theinput allows you to lock the frequency output to an external reference, such asthe Fluke Calibration 910R Rubidium Standard, for applications where high clockaccuracy or use of a common reference frequency is important. The frequencyreference output allows a UUT to be frequency locked to the 96040A internalreference clock. This configuration is often required to reduce frequencyoffset errors that may occur between the reference source and the UUT.

Simplify frequency response tests with96040A sweep functions

RF applications often require a frequencysweep. The 96040As sweep functions simplify the application of manual legacy spectrumanalyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for walk-away" efficiency

In a typical automated RF calibrationprocess, the operator must frequently intervene to change test setups, thuslimiting the benefits that can be realized by the automation. Walk-awayautomation can increase calibration system capacity by up to 25 percent usingprocedures you develop in MET/CAL Plus Calibration Management Software. Forexample, the manufacturers calibration procedure for calibrating the Agilent E4407B 26.5 GHzspectrum analyzer requires 27 different and complex test setups. On the otherhand, the 96040A, used with MET/CAL Plus Calibration Management Software, canperform the major core of required tests with a single setup. Only sixadditional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by FlukeCalibration for the 9640A models can be used by the 96040A in 9640A emulationmode. Optimized automated procedures can save time for the operators byallowing them to leave the system running while attending to other work. Forexample, the E4407B MET/CAL procedure for the legacy 9640A, running inemulation mode on the 96040A, allows for a total 90 minutes of walkaway" time withinthe total two-hour calibration runtime.

Using the 96040A with other automationsolutions

The 96040A is also integrated easily intoexisting automated systems and software. The time savings and efficiency gainsoffered by the 96040A can be realized by structuring test sequences to takefull advantage of its connect once measure many" capabilities.

The 96040A is designed to match or exceedthe performance and functionality of the HP3335A and HP8662/3A in calibrationsystems. With HP3335A and HP8662/3A GPIB command emulation as standard,replacing these popular but obsolete and difficult-to-maintain products becomesjust a plug-and-play substitution.

96040A summary specifications*

Frequency specifications

Level specifications
(50 Ω output, see extended specifications for 75 Ω)

Range

1 mHz to 4 GHz

-130 to +24 dBm to 125 MHz, 14 dBm at 4 GHz (leveled)

Resolution

10 µHz

0.001 dB

Accuracy

± 0.05 ppm ± 5 µHz

Down to -48 dBm: ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz
10 MHz to 128 MHz: ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm

Attenuation

± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB
Relative to +10 dBm, 10 Hz to 128 MHz

VSWR

≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 xf (GHz)

Harmonics and spurious

–60 dBc harmonics, –78 dBc spurious to 1 GHz

Phase noise at 1 GHz

–144 dBc/Hz, typical, at 10 kHz to 100 kHz offset

Modulation

AM, FM, PM, internal and external. Frequency pull and external leveling

Frequency sweep

1 mHz to 4 GHz. Linear or Logarithmic. Stop-Start or Center-Span

Frequency counter

Internal 50 MHz frequency counter

Temperature

Operating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance; Storage: -20 °C to +70 °C.

Standard interfaces

IEEE-488.2 (GPIB)

GPIB command emulation

9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.

Dimensions (HxWxD)

146 mm x 442 mm x 551 mm (5.8 in x 17.4 in x 21.7 in) including handles Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit

Weight

18 kg (40 lb)

*Key specifications summary. Refer to the extended specifications for full and detailed specifications.

型號(hào)

描述

96040A

4 GHz RF Reference Source including 50 Ω Leveling Head

96040A/75

4 GHz RF Reference Source including 50 Ω and 75 Ω Leveling Heads

靖江中諾儀器有限公司為福祿克中國(guó)總代理,歡迎!


感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN

智慧城市網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.zvwid.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),智慧城市網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
主站蜘蛛池模板: 久久中文字幕免费 | 亚洲国产精品成人综合色在线婷婷 | 射欧美| 97精品国产97久久久久久免费 | 色姑娘天天综合网 | 无码人妻久久一区二区三区蜜桃 | 欧美日日操 | 在线免费国产 | 国产午夜精品理论片 | 国产精品九九久久99视频 | 国产不卡一区二区三区在线观看 | 亚洲美乳中文字幕 | 99久热精品免费观看四虎 | 日韩欧美国产综合 | 在线观看免费av网站 | 国产欧美日韩视频 | 中文字幕二区在线 | 成人看片免费 | 色999在线 | 欧美久久久久久久久久久久 | 久久久久无码精品国产人妻无码 | 亚洲呦女专区 | 国内精品视频在线免费观看 | 国产成人无码a区在线视频无码DVD | 中文字幕亚洲情99在线 | 精品亚洲在线 | 免费国产在线无码 | 国产不卡一级无码视频 | av资源在线看 | 激情亚洲六月激情 | 秋霞久久久 | 多人伦精品一区二区三区视频 | 国产欧美在线播放视频 | 久亚洲一线产区二线产区三线区 | 一二三区中文字幕视频在线观看 | 曰韩人妻无码一区二区三区综合部 | 精品久久久久一区二区 | 最新久久免费视频 | 麻豆极品JK丝袜自慰喷水久久 | 亚洲av成人无码久久精品 | 日韩精品一区二区三区免费视频喜 |